[Please be sure to read the instruction manual]
[Generic Name]
Home Low-Frequency Therapy Device
[Product Name]
ATEX Low-Frequency Therapy Device Neck Massager AX-HK115
[Contraindications/Prohibitions]
Do not use with the following electrical medical devices:
- Implantable electrical medical devices susceptible to electromagnetic interference, such as pacemakers and implantable cardioverter-defibrillators
- Wearable electrical medical devices, such as electrocardiographs
This may cause electrical medical equipment to malfunction, which is dangerous.
This product contains a rechargeable battery.
Do not throw the product into fire, heat it, or charge, use, or leave it in high or low temperatures.
This may cause overheating, fire, or explosion.
Do not use on any area other than the designated area, or on the following areas.
- Near the chest or heart
- Mucous membranes, elbows, knees, and other joints
- Over post-surgical scars, wounds, and areas inflamed by acne or pimples
- Areas with inflamed skin
- Areas where plastic surgery has been performed, or areas with implanted metal, plastic, or silicone implants
- Areas with tattoos
The following people should consult a doctor before use:・People with abnormal blood pressure
・People with malignant tumors
・People with heart problems
・People from the early stages of pregnancy to immediately after childbirth
・People with sensory impairments due to severe peripheral circulatory disorders such as diabetes
・People with atopic dermatitis
・People with sensitive or fragile skin
・People with circulatory disorders
・People with cranial nerve abnormalities (epilepsy, etc.)
・People with a body temperature of 38°C or higher (fever stage) Example: During periods of severe acute inflammatory symptoms (fatigue, chills, blood pressure fluctuations, etc.), or when feeling weak
・People with skin abnormalities near the application area (infection, wound, etc.)
・People requiring rest or who are not feeling well
・People with acute "painful" conditions such as spinal fractures, sprains, or pulled muscles
・Other people receiving medical treatment
Do not allow infants or children to touch or use the device while it is on.
This may result in an unexpected accident.
Do not allow metal or other objects to come into contact with the live parts. This may cause a short circuit, overheating, or malfunction.
Do not use at the same time as other medical devices.
Doing so may be harmful to your health.
Do not immerse the unit in water or wash it with water.
Doing so may cause electric shock, short circuit, or fire.
Do not place the current-carrying part near the throat.
Check the product for damage before use.
Do not use if damaged.
If you experience any abnormalities in your body or skin after use, discontinue use and consult a doctor.
This may be harmful to your health or worsen your symptoms.
If you experience severe pain or redness on your skin, discontinue use immediately.
This may cause burns or injury.
If no effect is seen after use, consult a doctor or specialist.
[Item Specifications]
Category: Machinery and Equipment 78
Home Electrical Therapy Device (Class II)
Classification: Controlled Medical Device 70986000
Generic Name: Home Low-Frequency Therapy Device
Market Name: Low-Frequency Therapy Device Neck Massager
Product Number: AX-HK115
Medical Device Certification Number: 305AGBZX00039000v
Purpose or Effect of Use: Relief of stiff shoulders, prevention of atrophy of numb muscles, and massage effect.
For general household use.
Power Supply: DC 5V 1A (only for models marked with this symbol)
Continuous Use Time: Approximately 2 hours
Charging Time: Approximately 3 hours
Frequency: Approximately 7-70Hz
Rated Output Voltage: Approximately 42V
Maximum Output Current: Approximately 8mA
Pulse Width: Approximately 98µs
Rechargeable Battery: 3.7V 120mAh
Timer Duration: Approximately 15 minutes
Dimensions: Approximately 440mm W x 32mm L x 17mm H
Weight: Approximately 80g
Power Cord: Approximately 95cm
Materials:
Body: Silicon, Neodymium Magnet, ABS Resin
Conductive Parts: Conductive Silicon
Internal Circuit Box: ABS Resin
Country of Origin: China
Manufacturer: U YOUNG APPLIANCE MFG, (XIAMEN) CO, LTD
Manufacturer/Distributor: ATEX Co., Ltd.
[Usage Precautions]
Do not damage, modify, forcibly bend, pull, or twist the USB cable. Also, do not place heavy objects on or pinch it. Doing so may cause electric shock, short circuits, or fire.
Do not wrap the USB cable around the device when storing it.
This may put stress on the cord and cause it to break, resulting in a short circuit or fire.
Do not allow metal or debris to come into contact with the USB terminal.
Doing so may cause electric shock, short circuits, or fire.
When cleaning, always unplug the USB cable from the device and power outlet. Also, do not plug or unplug with wet hands.
Doing so may cause electric shock or injury.
When unplugging the USB cable, hold the terminal, not the cord, and pull out.
Doing so may cause electric shock, short circuits, or fire.
If you notice a malfunction, immediately stop using the device and turn off the power. Doing so may cause accidents or injury.
Do not apply strong impacts to the device.
Doing so may cause malfunctions or accidents.
Do not modify the device. Also, if the device malfunctions, do not attempt to repair it yourself; instead, contact your retailer or our customer service.
Doing so may cause fire, electric shock, or injury.
Do not use in humid places such as bathrooms.
(This product is not waterproof.)
This may cause electric shock or malfunction.
Do not place heavy objects on the unit or drop them.
This may result in malfunction or an accident.
Do not use the product under a bedding or with a blanket over it.
This may restrict breathing and cause suffocation.
Do not use within 30 minutes of eating.
This may cause poor health.
Do not use or store the product near hot objects, open flames, or in direct sunlight.
This may cause deformation, malfunction, or fire.
Do not use on any body other than the human body.
This may result in an accident or malfunction.
Do not forcefully stretch or bend the product.
This may result in an accident or malfunction.
This product uses magnets. Do not bring magnetic cards (credit cards, etc.) near the product.
This may cause the card to become unusable.
When using for the first time, start at level 1 and gradually adjust the strength to your liking.
Increasing the strength from the beginning may be harmful to your health.
Limit each use to 15 minutes.
Continuous use for extended periods of time may cause excessive stimulation, which may have the opposite effect or lead to injury.
Limit total usage time per day to 30 minutes or less.
Continuous use for extended periods of time may cause excessive stimulation to muscles and nerves, which may lead to the opposite effect or injury.
Remove any jewelry from contact with the device when using the device.
Doing so may result in an accident or malfunction.
Even if you will not be using the device for an extended period of time, charge it approximately once every three months.
Lack of use for extended periods of time may result in a decrease in functionality and may cause the internal rechargeable battery to malfunction.
When using the device, make sure that the entire current-carrying part is in contact with your skin.
The smaller the contact area with your skin, the stronger the stimulation.
Do not use any AC adapter other than one with a rated output of DC5V/1A and electric shock protection class II.
Doing so may result in malfunction or an accident.
[Name of Manufacturer/Distributor]
Manufacturer/Distributor: Atex Co., Ltd.
Inquiries: Customer Service Department
Telephone: 0120-48-6505
Manufacturer: U YOUNG APPLIANCE MFG. (XIAMAN) Co., Ltd.
Country of Origin: China
[Purpose of Use or Effects/Efficacy]
Relieves stiff shoulders, prevents atrophy of paralyzed muscles, and provides a massage effect.
For home use
Medical Device Classification: Specially Controlled Medical Device
Medical Device Certification (Approval) Number: 305AGBZX00039000
Equipped with 4 Modes
Simply wrap this low-frequency therapy device around your neck to target stiff muscles
Comfortable low-frequency waves between 7Hz and 70Hz relieve stiff muscles from the neck to shoulders.